HIGH-ACCURACY CORIOLIS FLOW & DENSITY MEASUREMENT

TCMP 7900 Coriolis Mass Flow Meter

PRO Series | TCMP 7900 Mass Flow Meter

TCM_5500_7900_TCD_9xxx_compact_remote-front_shadow_180425

The TRICOR PRO TCMP 7900 Coriolis Mass Flow Meter has a maximum mass flow rate of 7900 kg/hr (290 lb/min) or 1193 bbl/day and nominal size of DN15 (1/2”). This meter has an accuracy of 0.1% and withstands pressures up to 100 bar (1450 psi). The transmitter with Digital Signal Processing provides a modern HMI interface, strong logging functionality, and advanced diagnostics. Each Coriolis meter is mechanically balanced to ensure the best in class density measurement and overall performance.

Standard Pressure Rating: up to 100 bar 1450 psi
Mass Flow Rate (max.): 7900 kg/h290 lb/min
Volumetric Flow Rate (max.): 7900 l/h34.78 gpm, 1193 bbl/d (US)
Nominal Meter Size: DN151/2″
  • Robust, no moving parts
  • Increased productivity
  • Customized installation length
  • Considerable cost savings for installation
  • Excellent Repeatability (±0.05%), Accuracy (±0.1%)
  • Increased product quality
  • Advanced Transmitter Technology Upgrade/modernize in place
  • Optimized lifecycle management
FLOW RATE
Mass Flow Rate (max.): 7900 kg/h, 290 lb/min
Volumetric Flow Rate (max.): 7900 l/h, 34.78 gpm, 1193 bbl/d (US)
PRESSURE
Pressure Rating: up to 100 bar, 1450 psi
ACCURACY (LIQUIDS)¹
Basic Accuracy (Mass flow): ±0.1 % of flow rate
Repeatability (Mass flow): ±0.05 % of flow rate
Basic Accuracy (Volume flow): ±0.15 % of flow rate
Repeatability (Volume Flow): ±0.05 % of flow rate
Zero Stability: ±0.01 % of full scale
ACCURACY (GASES)
Basic Accuracy (Mass flow): ±0.5 % of flow rate
Repeatability Mass Flow: ±0.25 % of flow rate
DENSITY
Density Range: up to 2500 kg/m³, 2.5 g/cm³
Density Accuracy: Liquids ±1.0 kg/m³, ±0.001 g/cm³
Density Repeatability: ±0.5 kg/m³, ±0.0005 g/cm³
TEMPERATURE
Process Temperature Range: -40 °C … +100 °C (- 40 °F … +212 °F)
Optional Process Temperature Range: -60 °C … +200 °C (-76 °F … + 392°F)
Temperature Accuracy: ±1 °C ±0.5 % (±1.8 °F ± 0.5% of reading of reading)
Temperature Repeatability: ±0.2 °C (±0.36 °F )
MATERIALS OF CONSTRUCTION (wetted parts)
Tubes: 1.4404/AISI 316L
Case: 1.4404/AISI 316L
Flow Splitter: 1.4404/AISI 316L
Brazing Alloy: BNi-2
EX CERTIFICATIONS²
ATEX (Ex): Zone 1: Group IIC or IIB, T2…T4
ATEX (Exn): Zone 2: II 3G Ex nA IIC T2…T4 Gc
IECEx (Ex): Zone 1: Group IIC or IIB, T2…T4
cCSAus (Ex1): Class 1, Division 1: Group A, B, C, D or C, D, T2…T4

 

¹Stated flow accuracy combines the effects of repeatability, linearity and hystereis.

²Release pending.

This is a text block. Click the edit button to change this text.

 

TRICOR Coriolis Flow Meter TCM 7900 Pressure Drop Curves

 

 

 

TRICOR Coriolis Mass Flow Meters Accuracy Formula TRICOR Coriolis Mass Flow Meters Accuracy Curve