HIGH-ACCURACY CORIOLIS FLOW & DENSITY MEASUREMENT

PRO Series | TCMP 230K

PRO Series | TCMP 230K Coriolis Mass Flow Meter

The TRICOR PRO TCMP 230K Coriolis Mass Flow Meter has a maximum mass flow rate of 230,000 kg/hr (8450 lb/min) or 34,720 bbl/day and nominal size of DN80 (3”). This meter has an accuracy of 0.1% and withstands pressures up to 100 bar (1450 psi). The transmitter with Digital Signal Processing provides a modern HMI interface, strong logging functionality, and advanced diagnostics. Each Coriolis meter is mechanically balanced to ensure the best in class density measurement and overall performance.

Mass Flow Rate (max.): 230,000 kg/h8450 lb/min
Volumetric Flow Rate (max.): 230,000 l/h1013 gpm, 34,720 bbl/d (US)
Standard Pressure Rating: up to 100 bar1450 psi
Nominal Meter Size: DN803″
  • Robust, no moving parts
  • Increased productivity
  • Customized installation length
  • Considerable cost savings for installation
  • Excellent Repeatability (±0.05%), Accuracy (±0.1%)
  • Increased product quality
  • Advanced Transmitter Technology Upgrade/modernize in place
  • Optimized lifecycle management
[/trow]
FLOW RATE
Mass Flow Rate (max.): 230,000 kg/h, 8450 lb/min
Volumetric Flow Rate (max.): 230,000 l/h, 1013 gpm, 34,720 bbl/d (US)
PRESSURE
Standard Pressure Rating: up to 100 bar, 1450 psi
ACCURACY (LIQUIDS) Stated flow accuracy combines the effects of repeatability, linearity and hysteresis.
Basic Accuracy [Mass flow]: ±0.1 % of flow rate
Mass Flow Repeatability: ±0.05 % of flow rate
Basic Accuracy [Volume flow]: ±0.15 % of flow rate
Volume Flow Repeatability: ±0.05 % of flow rate
Zero Stability: ±0.01 % of full scale
ACCURACY (GASES)
Basic Accuracy [Mass flow]: ±0.5 % of flow rate
Mass Flow Repeatability: ±0.25 % of flow rate
DENSITY
Density Range: up to 2500 kg/m³, 2.5 g/cm³
Density Accuracy: ±1.0 kg/m³, ±0.001 g/cm³
Density Repeatability: ±0.5 kg/m³, ±0.0005 g/cm³
TEMPERATURE
Process Temperature Range: -40 °C … +100 °C (-40 °F … +212 °F )
Optional: -60 °C … +200 °C (-76 °F … +392 °F )
Temperature Accuracy: ±1 °C ±0.5 % of reading (±1.8 °F ± 0.5% of reading)
Temperature Repeatability: ±0.2 °C (±0.36 °F)
MATERIALS OF CONSTRUCTION (wetted parts)
Tubes: 1.4404/AISI 316L
Case: 1.4404/AISI 316L
Flow splitter: CF3M/1.4409
Option: NACE MR 0175/0103 compliant
EX CERTIFICATIONS²
ATEX: Zone 1: Ex db ia [ia Ga] IIC T* Gb
Zone 2: II 3G nR nA IIC T4
IECEx: Ex db ia [ia Ga] IIC T* Gb
cCSAus: Canadian Marking: Ex db ia [ia Ga] IIC T* Gb
US Zones Marking: Cl. 1, Zone 1 AEx db ia [ia Ga] IIC T4-T3 Gb
US Divisions Marking: Cl. 1, Div. 1 Group A, B, C and D, T*

 

¹Stated flow accuracy combines the effects of repeatability, linearity and hystereis.

²Release pending.

*Refer to EX certificate.

 

TRICOR Coriolis Flow Meter TCM 230K Pressure Drop Curves

 

TRICOR Coriolis Mass Flow Meters Accuracy Formula TRICOR Coriolis Mass Flow Meters Accuracy Curve