HIGH-ACCURACY CORIOLIS FLOW & DENSITY MEASUREMENT

TCMP 0325 Coriolis Mass Flow Meter

PRO Series | TCMP 0325 Coriolis Mass Flow Meter

The TRICOR PRO TCMP 0325 Coriolis meter is a combination Density meter and Mass Flow Meter with a maximum mass flow rate of 325 kg/hr (12 lb/min) or 49 bbl/day, and a nominal size of DN4 (1/8”) that provides native measurement outputs of density, mass flow, process temperature, volume flow, total mass, and total volume. This meter has an accuracy of 0.1% and withstands pressures up to 200 bar (2900 psi). This meter sports a Digital Signal Processing transmitter to provide a modern HMI interface, strong logging functionality, and advanced diagnostics. Each Coriolis meter is mechanically balanced to ensure the best in class density measurement and overall performance.

Mass Flow Rate (max.): 325 kg/h12 lb/min
Volumetric Flow Rate (max.): 325 l/h1.43 gpm, 49 bbl/d (US)
Standard Pressure Rating: up to 200 bar2900 psi
Optional Pressure Rating: up to 345 bar5000 psi
Nominal Meter Size: DN41/8″
  • Robust, no moving parts
  • Increased productivity
  • Customized installation length
  • Considerable cost savings for installation
  • Excellent Repeatability (±0.05%), Accuracy (±0.1%)
  • Increased product quality
  • Advanced Transmitter Technology Upgrade/modernize in place
  • Optimized lifecycle management
[/trow]
FLOW RATE
Mass Flow Rate (max.): 325 kg/h, 12 lb/min
Volumetric Flow Rate (max.): 325 l/h, 1.43 gpm, 49 bbl/d (US)
PRESSURE
Pressure Rating: up to 200 bar, 2900 psi
Optional Pressure Rating: up to 345 bar, 5,000 psi
ACCURACY (LIQUIDS)¹
Basic Accuracy [Mass flow]: ±0.1 % of flow rate
Mass Flow Repeatability: ±0.05 % of flow rate
Basic Accuracy [Volume flow]: ±0.15 % of flow rate
Volume Flow Repeatability: ±0.05 % of flow rate
Zero Stability: ±0.01 % of full scale
ACCURACY (GASES)
Basic Accuracy [Mass flow]: ±0.5 % of flow rate
Mass Flow Repeatability: ±0.25 % of flow rate
DENSITY
Density Range: up to 2500 kg/m³, 2.5 g/cm³
Density Accuracy: Liquids ±1.0 kg/m³, ±0.001 g/cm³
Density Repeatability: ±0.5 kg/m³, ±0.0005 g/cm³
TEMPERATURE
Process Temperature Range: -76 °F … +392 °F (-60 °C … +200 °C)
Temperature Accuracy: ±1 °C ±0.5 % of reading (±1.8 °F ± 0.5% of reading)
Temperature Repeatability: ±0.2 °C (±0.36 °F)
MATERIALS OF CONSTRUCTION (wetted parts)
Tubes: 1.4404/AISI 316L
Case: 1.4404/AISI 316
Flow splitter: 1.4404/AISI 316L
Brazing Alloy: BNi-2
EX CERTIFICATIONS²
ATEX: Zone 1: Ex db ia [ia Ga] IIC T* Gb
Zone 2: II 3G nR nA IIC T4
IECEx: Ex db ia [ia Ga] IIC T* Gb
cCSAus: Canadian Marking: Ex db ia [ia Ga] IIC T* Gb
US Zones Marking: Cl. 1, Zone 1 AEx db ia [ia Ga] IIC T4-T3 Gb
US Divisions Marking: Cl. 1, Div. 1 Group A, B, C and D, T*

 

¹Stated flow accuracy combines the effects of repeatability, linearity and hystereis.

²Release pending.

*Refer to EX certificate.

 

TRICOR Coriolis Flow Meter TCM 0325 Pressure Drop Curves

 