TRICOR Coriolis Flow Transmitters 9000 Series
PRO Series | TCD 9100 Coriolis Transmitter
Features
DSP
Reliable in challenging measurements
Graphical Display
Easy maintenance and support
SD-Card
Storage: logging, documents, firmware updates
Extended Logging Functionality
Improved process control
Extremely Fast
Accurate in short dosing cycles
Technical Specifications
GENERAL | |
Display: | 240 x 160 pixels, 6 programmable views |
Supply Voltage: | 20…27 V DC or 100…240 V DC |
Power Consumption: | 7.5 W/15 VA |
Interface: | HART® 7.2, Profibus PA/DP, Modbus® RTU, Slot for one Plug-in I/O Card |
Cables: | Standard industrial signal cable up to 200 m long, 2x screened pairs or 4-wire overall |
Housing Material: | Aluminum |
Protection Class: | IP 65; Optional IP67/NEMA 4X to IEC 529 and DIN 40050 (1 mH20 for 30 min.) |
Temperature: | Ambient temp Transmitter: -40 °C … +60 °C (-40 °F … +140 °F) Humidity max. 95 % Ambient temp Display: -20 °C … +60 °C (-4 °F … +140 °F) Storage and Transport: -20 °C … +70 °C (-4 °F … +158 °F) |
PLUG-IN I/O CARD | One optional plug-In I/O-Card with three configurable channels. |
Available Plug-In I/O Cards: | Option 1: [CH2, CH3, CH4][Signal I/O, Signal I/O, Signal I/O] |
Option 2: [CH2, CH3, CH4][Signal I/O, Signal I/O, Relay] | |
Signal I/O: | Configuable universal I/O channel Frequency, Digital, Current-Output or Digital-Input, Galvanically Isolated Isolation voltage 500 V |
Current Output | 0 … 20 mA or 4 … 20 mA (CH1 only 4 … 20 mA) |
Digital Output: | Pulse: 41.6 μs … 5 s pulse duration, Frequency: 0 … 10 kHz, Active (short-circuit-protected): 0 … 24V DC, 110 mA, Passive: 3 … 30 V DC, max. 110 mA |
Relay: | Voltage-free contact, 30 V AC, 100 mA |
Digital Input: | 15 … 30 V DC, 2 … 15 mA |
EX CERTS* | |
ATEX (Ex): | Zone 1: Group IIC or IIB, T2…T4 |
ATEX (Exn): | Zone 2: II 3G Ex nA IIC T2…T4 Gc |
IECEx (Ex): | Zone 1: Group IIC or IIB, T2…T4 |
cCSAus (Ex1): | Class 1, Division 1: Group A, B, C, D or C, D, T2…T6 For Ex1 the electronic is only available in aluminum housing. *Release pending. |
PRO Series | TCD 9200 Coriolis Transmitter
Features
DSP
Reliable in challenging measurements
Graphical Display
Easy maintenance and support
SD-Card
Storage: logging, documents, firmware updates
Extended Logging Functionality
Improved process control
Extremely Fast
Accurate in short dosing cycles
Technical Specifications
GENERAL | |
Display: | 240 x 160 pixels, 6 programmable views |
Supply Voltage: | 20…27 V DC or 100…240 V DC |
Power Consumption: | 7.5 W/15 VA |
Interface: | HART® 7.2, Profibus PA/DP, Modbus® RTU, Slot for one Plug-in I/O Card |
Cables: | Standard industrial signal cable up to 200 m long, 2x screened pairs or 4-wire overall |
Housing Material: | Aluminum |
Protection Class: | IP 65; Optional IP67/NEMA 4X to IEC 529 and DIN 40050 (1 mH20 for 30 min.) |
Temperature: | Ambient temp Transmitter: -40 °C … +60 °C (-40 °F … +140 °F) Humidity max. 95 % Ambient temp Display: -20 °C … +60 °C (-4 °F … +140 °F) Storage and Transport: -20 °C … +70 °C (-4 °F … +158 °F) |
PLUG-IN I/O CARD | One optional plug-In I/O-Card with three configurable channels. |
Available Plug-In I/O Cards: | Option 1: [CH2, CH3, CH4][Signal I/O, Signal I/O, Signal I/O] Option 2: [CH2, CH3, CH4][Signal I/O, Signal I/O, Relay] |
Signal I/O: | Configuable universal I/O channel Frequency, Digital, Current-Output or Digital-Input, Galvanically Isolated Isolation voltage 500 V |
Current Output | 0 … 20 mA or 4 … 20 mA (CH1 only 4 … 20 mA) |
Digital Output: | Pulse: 41.6 μs … 5 s pulse duration, Frequency: 0 … 10 kHz, Active (short-circuit-protected): 0 … 24V DC, 110 mA, Passive: 3 … 30 V DC, max. 110 mA |
Relay: | Voltage-free contact, 30 V AC, 100 mA |
Digital Input: | 15 … 30 V DC, 2 … 15 mA |
EX CERTS | |
ATEX (Ex): | Zone 1: Group IIC or IIB, T2…T4 |
ATEX (Exn): | Zone 2: II 3G Ex nA IIC T2…T4 Gc |
IECEx (Ex): | Zone 1: Group IIC or IIB, T2…T4 |
cCSAus (Ex1): | Class 1, Division 1: Group A, B, C, D or C, D, T2…T6 For Ex1 the electronic is only available in aluminum housing. *Release pending. |