Notice: Undefined index: fontdeck_js in /opt/bitnami/apps/wordpress/htdocs/wp-content/themes/tricor/header.php on line 176
TRICOR TCD Coriolis Mass Flow Transmitter
HIGH-ACCURACY CORIOLIS FLOW & DENSITY MEASUREMENT

TRICOR Coriolis TCE 9000 Series

TRICOR Coriolis Flow Transmitters 9000 Series

PRO Series | TCD 9100 Coriolis Transmitter

TCD_9100-front_screen_shadow_180425

Features

DSP
Reliable in challenging measurements

Graphical Display
Easy maintenance and support

SD-Card
Storage: logging, documents, firmware updates

Extended Logging Functionality
Improved process control

Extremely Fast
Accurate in short dosing cycles

Technical Specifications

 

GENERAL
Display: 240 x 160 pixels, 6 programmable views
Supply Voltage: 20…27 V DC or 100…240 V DC
Power Consumption: 7.5 W/15 VA
Interface: HART® 7.2, Profibus PA/DP, Modbus® RTU, Slot for one Plug-in I/O Card
Cables: Standard industrial signal cable up to 200 m long, 2x screened pairs or 4-wire overall
Housing Material: Aluminum
Protection Class: IP 65; Optional IP67/NEMA 4X to IEC 529 and DIN 40050 (1 mH20 for 30 min.)
Temperature: Ambient temp Transmitter: -40 °C … +60 °C (-40 °F … +140 °F) Humidity max. 95 %
Ambient temp Display: -20 °C … +60 °C (-4 °F … +140 °F)
Storage and Transport: -20 °C … +70 °C (-4 °F … +158 °F)
PLUG-IN I/O CARD One optional plug-In I/O-Card with three configurable channels.
Available Plug-In I/O Cards: Option 1: [CH2, CH3, CH4][Signal I/O, Signal I/O, Signal I/O]
Option 2: [CH2, CH3, CH4][Signal I/O, Signal I/O, Relay]
Signal I/O: Configuable universal I/O channel Frequency, Digital, Current-Output or Digital-Input, Galvanically Isolated Isolation voltage 500 V
Current Output 0 … 20 mA or 4 … 20 mA (CH1 only 4 … 20 mA)
Digital Output: Pulse: 41.6 μs … 5 s pulse duration, Frequency: 0 … 10 kHz, Active (short-circuit-protected): 0 … 24V DC, 110 mA, Passive: 3 … 30 V DC, max. 110 mA
Relay: Voltage-free contact, 30 V AC, 100 mA
Digital Input: 15 … 30 V DC, 2 … 15 mA
EX CERTS*
ATEX (Ex): Zone 1: Group IIC or IIB, T2…T4
ATEX (Exn): Zone 2: II 3G Ex nA IIC T2…T4 Gc
IECEx (Ex): Zone 1: Group IIC or IIB, T2…T4
cCSAus (Ex1): Class 1, Division 1: Group A, B, C, D or C, D, T2…T6
For Ex1 the electronic is only available in aluminum housing.
*Release pending.

PRO Series | TCD 9200 Coriolis Transmitter

TCD_9200_180425_front__screen_180425

Features

DSP
Reliable in challenging measurements

Graphical Display
Easy maintenance and support

SD-Card
Storage: logging, documents, firmware updates

Extended Logging Functionality
Improved process control

Extremely Fast
Accurate in short dosing cycles

Technical Specifications

GENERAL
Display: 240 x 160 pixels, 6 programmable views
Supply Voltage: 20…27 V DC or 100…240 V DC
Power Consumption: 7.5 W/15 VA
Interface: HART® 7.2, Profibus PA/DP, Modbus® RTU, Slot for one Plug-in I/O Card
Cables: Standard industrial signal cable up to 200 m long, 2x screened pairs or 4-wire overall
Housing Material: Aluminum
Protection Class: IP 65; Optional IP67/NEMA 4X to IEC 529 and DIN 40050 (1 mH20 for 30 min.)
Temperature: Ambient temp Transmitter: -40 °C … +60 °C (-40 °F … +140 °F) Humidity max. 95 %
Ambient temp Display: -20 °C … +60 °C (-4 °F … +140 °F)
Storage and Transport: -20 °C … +70 °C (-4 °F … +158 °F)
PLUG-IN I/O CARD One optional plug-In I/O-Card with three configurable channels.
Available Plug-In I/O Cards: Option 1: [CH2, CH3, CH4][Signal I/O, Signal I/O, Signal I/O]
Option 2: [CH2, CH3, CH4][Signal I/O, Signal I/O, Relay]
Signal I/O: Configuable universal I/O channel Frequency, Digital, Current-Output or Digital-Input, Galvanically Isolated Isolation voltage 500 V
Current Output 0 … 20 mA or 4 … 20 mA (CH1 only 4 … 20 mA)
Digital Output: Pulse: 41.6 μs … 5 s pulse duration, Frequency: 0 … 10 kHz, Active (short-circuit-protected): 0 … 24V DC, 110 mA, Passive: 3 … 30 V DC, max. 110 mA
Relay: Voltage-free contact, 30 V AC, 100 mA
Digital Input: 15 … 30 V DC, 2 … 15 mA
EX CERTS
ATEX (Ex): Zone 1: Group IIC or IIB, T2…T4
ATEX (Exn): Zone 2: II 3G Ex nA IIC T2…T4 Gc
IECEx (Ex): Zone 1: Group IIC or IIB, T2…T4
cCSAus (Ex1): Class 1, Division 1: Group A, B, C, D or C, D, T2…T6
For Ex1 the electronic is only available in aluminum housing.
*Release pending.