PRO Plus Series | TCMQ 070K Mass Flow Meter
The TRICOR PRO Plus TCMQ 070K Coriolis Mass Flow Meter has a maximum mass flow rate of 70,700 kg/hr (2600 lb/min) or 10,700 bbl/day and nominal size of DN50 (2”). This meter has an accuracy of 0.1% and withstands pressures up to 100 bar (1450 psi). The compact footprint of this meter allows for installation into tight spaces. The transmitter with Digital Signal Processing provides a modern HMI interface, strong logging functionality, and advanced diagnostics.
Standard Pressure Rating: | up to 100 bar | 1450 psi |
Mass Flow Rate (max.): | 70,700 kg/h | 2600 lb/min |
Volumetric Flow Rate (max.): | 70,700 l/h | 311 gpm, 10,700 bbl/d (US) |
Nominal Meter Size: | DN50 | 2″ |
- Fast dosage, short response time (max. 10 ms)
- High dosing accuracy
- 100 Hz refresh rate for all outputs
- Suitable for pump monitoring, fast control circuits
- Extremely short installation length
- Best fit in most system configurations
- High zero stability, drift free
- Accuracy combined with long-term stability
FLOW RATE | |
Mass Flow Rate (max.): | 70,700 kg/h, 2600 lb/min |
Volumetric Flow Rate (max.): | 70,700 l/h, 311 gpm, 10,700 bbl/d (US) |
PRESSURE | |
Pressure Rating: | up to 100 bar, 1450 psi |
ACCURACY (LIQUIDS)¹ | |
Basic Accuracy (Mass flow): | ±0.1 % of flow rate |
Repeatability (Mass flow): | ±0.05 % of flow rate |
Basic Accuracy (Volume flow): | ±0.15 % of flow rate |
Repeatability (Volume Flow): | ±0.05 % of flow rate |
Zero Stability: | ±0.003 % of full scale |
ACCURACY (GASES) | |
Basic Accuracy (Mass flow): | ±0.35 % of flow rate |
Repeatability Mass Flow: | ±0.05 % of flow rate |
DENSITY | |
Density Range: | up to 5000 kg/m³, 5.0 g/cm³ |
Density Accuracy: | ±5.0 kg/m³ (option: ±5.0 g/cm³) [±0.005 g/cm³ (option: ±0.0005 g/cm³)] |
Density Repeatability: | ±0.25 kg/m³, ±0.00025 g/cm³ |
Brix: | 0.1°Brix (1000/m³) |
TEMPERATURE | |
Process Temperature Range: | -60 °C … +200 °C (- 76 °F … +392 °F) |
Temperature Accuracy: | ±0.5°C ±0.25 % of reading (±0.9°F ± 0.25% of reading) |
MATERIALS OF CONSTRUCTION (wetted parts) | |
Sensor: | 1.4404/AISI 316L |
Case: | 1.4301/AISI 304L |
Tubes: | 1.4404/AISI 316L |
Flow Splitter: | 1.4404/AISI 316L |
EX CERTIFICATIONS² | |
ATEX: | Zone 1: Group IIC, T3…T6 Zone 21: Group IIIC, T3…T6 |
IECEx: | Zone 1: Group IIC, T3…T6 Zone 21: Group IIIC, T3…T6 |
cCSAus: | Class I, II, III, Division I: Groups A, B, C, D, E, F, G Class I, Zone 1, Zone 21 IIIC, Zone 20 IIIC |
EAC (TR-CU): | Zone 1: Group IIC, T3…T6 Zone 21: Group IIIC, T3…T6 |
¹Stated flow accuracy combines the effects of repeatability, linearity and hystereis.
²Release pending.