HIGH-ACCURACY CORIOLIS FLOW & DENSITY MEASUREMENT

TCMQ 070K Coriolis Mass Flow Meter

PRO Plus Series | TCMQ 070K Mass Flow Meter

The TRICOR PRO Plus TCMQ 070K Coriolis Mass Flow Meter has a maximum mass flow rate of 70,700 kg/hr (2600 lb/min) or 10,700 bbl/day and nominal size of DN50 (2”). This meter has an accuracy of 0.1% and withstands pressures up to 100 bar (1450 psi). The compact footprint of this meter allows for installation into tight spaces. The transmitter with Digital Signal Processing provides a modern HMI interface, strong logging functionality, and advanced diagnostics.

Standard Pressure Rating: up to 100 bar 1450 psi
Mass Flow Rate (max.): 70,700 kg/h2600 lb/min
Volumetric Flow Rate (max.): 70,700 l/h311 gpm, 10,700 bbl/d (US)
Nominal Meter Size: DN502″
  • Fast dosage, short response time (max. 10 ms)
  • High dosing accuracy
  • 100 Hz refresh rate for all outputs
  • Suitable for pump monitoring, fast control circuits
  • Extremely short installation length
  • Best fit in most system configurations
  • High zero stability, drift free
  • Accuracy combined with long-term stability

 

FLOW RATE
Mass Flow Rate (max.): 70,700 kg/h, 2600 lb/min
Volumetric Flow Rate (max.): 70,700 l/h, 311 gpm, 10,700 bbl/d (US)
PRESSURE
Pressure Rating: up to 100 bar, 1450 psi
ACCURACY (LIQUIDS)¹
Basic Accuracy (Mass flow): ±0.1 % of flow rate
Repeatability (Mass flow): ±0.05 % of flow rate
Basic Accuracy (Volume flow): ±0.15 % of flow rate
Repeatability (Volume Flow): ±0.05 % of flow rate
Zero Stability: ±0.003 % of full scale
ACCURACY (GASES)
Basic Accuracy (Mass flow): ±0.35 % of flow rate
Repeatability Mass Flow: ±0.05 % of flow rate
DENSITY
Density Range: up to 5000 kg/m³, 5.0 g/cm³
Density Accuracy: ±5.0 kg/m³ (option: ±5.0 g/cm³)
[±0.005 g/cm³ (option: ±0.0005 g/cm³)]
Density Repeatability: ±0.25 kg/m³, ±0.00025 g/cm³
Brix: 0.1°Brix (1000/m³)
TEMPERATURE
Process Temperature Range: -60 °C … +200 °C (- 76 °F … +392 °F)
Temperature Accuracy: ±0.5°C ±0.25 % of reading (±0.9°F ± 0.25% of reading)
MATERIALS OF CONSTRUCTION (wetted parts)
Sensor: 1.4404/AISI 316L
Case: 1.4301/AISI 304L
Tubes: 1.4404/AISI 316L
Flow Splitter: 1.4404/AISI 316L
EX CERTIFICATIONS²
ATEX: Zone 1: Group IIC, T3…T6
Zone 21: Group IIIC, T3…T6
IECEx: Zone 1: Group IIC, T3…T6
Zone 21: Group IIIC, T3…T6
cCSAus: Class I, II, III, Division I: Groups A, B, C, D, E, F, G
Class I, Zone 1, Zone 21 IIIC, Zone 20 IIIC
EAC (TR-CU): Zone 1: Group IIC, T3…T6
Zone 21: Group IIIC, T3…T6

 

¹Stated flow accuracy combines the effects of repeatability, linearity and hystereis.

²Release pending.

 

 

 

Accuracy Curve – Mass Flow

 

Accuracy Curve – Volumetric Flow