| | | | | | General | | Display | Graphic, 132 x 32 dot
| Supply voltage
| 24 VDC, ± 20%, option 110 VAC
| | Programming | via front keyboard
| | Interface | RS 485, option HART, option Foundation Fieldbus
| | EMC | according to EN 50 081-2 and EN 50 082-2
| Power Consumption
| max. 4W
| Explosion-proof Housing | | Dimensions | see data sheet
| | Connections | internal clamp terminals, 1/2" female NPT cable gland
| | Material | aluminum diecast
| Protection class
| IP 67
| | Weight | approx. 2kg
| | Temperature | operation: -20 to 50*C, storage & transport: -20 to 70*C
| Panel-mounted housing | | Dimensions | 96 x 96 x 83 mm (h x w x d)
| | Connections | rear clamp terminals
| | Material | Noryl | Protection class
| front: IP 40, rear: IP 30
| | Weight | approx 500g
| | Temperature | operation: 0 to 50*C storage & transport: -20 to 70*C
| Analog Outputs | Two current outputs
| 4-20mA passive, two-wire isolated
| | Resolution | 14 bit
| | Linearity | ±0.05% of full scale
| Temperature drift
| 0.05% per 10K
| | Load | < 800 Ohms
| Output value
| programmable: flow, total, density, temperature
| Pulse Output | Frequency range
| 0.5-10,000 Hz
| Output signal
| active push-pull output of flow rate or cycle output
| Status In- and Output | Status output
| programmable (push pull)
| Control input
| programmable | |   | |
| |
| |
| | | |
|
|