| | | | | | SPECIFICATIONS: | Mass Flow Rate (max.)
| 65,000 Kg/Hr (2400 Lbs/Min) | Volumetric Flow Rate (max.)
| 288 gpm (65,000 lph)
| | Nominal Meter Size
| 2" | | Pressure Rating | 1450 psig (100 bar)
| ACCURACY: Basic Accuracy = ±0.10%of flow rate Zero Stability = .257 lbs/min (7.0 kg/hr) Basic accuracy ±0.10% of flow rate + zero stability * 100% flow rate. (Stated accuracy combines the effects of repeatability, linearity, and hysteresis.) DENSITY: Density Accuracy: Liquids: ±1.0 kg/m3, ±0.001 g/cm 3 Density Repeatability: ±0.5 kg/m3, ±0.0005 g/cm3 Density Range: Up to 5,000 kg/m3 (5 g/cm3 , 5.0 S.G.)
|  | | TEMPERATURE: Media Temperature Range: -150 to 302°F (-100 to 150°C) Temperature Accuracy: ±1.0°C, ±0.5% of reading, repeatability ±0.1%. May require a special platinum RTD for cold temps (-40° and below). PRESSURE: Process Pressure Effect: Mass Flow Accuracy: ±0.001% of rate per PSI Density Accuracy: ±0.00003 g/cm3 per PSI MATERIALS OF CONSTRUCTION: Wetted Parts: 316L SS Seamless tubing Case: 304 SS Casting: OF3M (316 SS) Brazing Alloy |

| |
| |
| |
| | | |
|
|