TCM-3100

     TRICOR

       Products










 

SPECIFICATIONS:

 Mass Flow Rate (max.)

 3100 Kg/Hr (110 Lbs/Min)
 Volumetric Flow Rate (max.)
 13.19 gpm (3000 lph)

 Nominal Meter Size

 1/4"

 Pressure Rating

 2900 psig (200 bar)

 


ACCURACY:

Basic Accuracy = ±0.1% of flow rate    

Zero Stability = .0114 lbs/min (0.31 kg/hr)

Basic accuracy ±0.10% of flow rate + zero stability * 100% flow rate. (Stated accuracy combines the effects of repeatability, linearity,
and hysteresis.)


 

DENSITY:

Density Accuracy: Liquids: ±0.002 kg/ltr

Density Repeatability: ±0.5 kg/m3, ±0.0005 g/cm3 

Density Range: Up to 4,500 kg/m3 (4.5 g/cm 3 , 4.5 S.G.)

 


TEMPERATURE:

Media Temperature Range: -150 to 302°F (-100 to 150°C)

Temperature Accuracy: ±1.0°C, ±0.5% of reading, repeatability ±0.1%.  May require a special platinum RTD for cold temps
(-40° and below).

PRESSURE:

Process Pressure Effect:

Mass Flow Accuracy: ±0.001% of rate per PSI

Density Accuracy: ±0.00003 g/cm3 per PSI

 

MATERIALS OF CONSTRUCTION:

Wetted Parts: 

316L SS

Seamless tubing

Case:

304 SS

Casting:

OF3M (316 SS)

Brazing Alloy