HIGH-ACCURACY CORIOLIS FLOW & DENSITY MEASUREMENT

TCMP 0650 Coriolis Mass Flow Meter

PRO Series | TCMP 0650 Coriolis Mass Flow Meter

The TRICOR PRO TCMP 0650 Coriolis Mass Flow Meter has a maximum mass flow rate of 650 kg/hr (24 lb/min) or 98 bbl/day and nominal size of DN4 (1/8”). This meter has an accuracy of 0.1% and withstands pressures up to 200 bar (2900 psi). The transmitter with Digital Signal Processing provides a modern HMI interface, strong logging functionality, and advanced diagnostics. Each Coriolis meter is mechanically balanced to ensure the best in class density measurement and overall performance.

Mass Flow Rate (max.): 650 kg/h24 lb/min
Volumetric Flow Rate (max.): 650 l/h2.86 gpm, 98 bbl/d (US)
Standard Pressure Rating: up to 200 bar2900 psi
Optional Pressure Rating: up to 345 bar5000 psi
Nominal Meter Size: DN41/8″
  • Robust, no moving parts
  • Increased productivity
  • Customized installation length
  • Considerable cost savings for installation
  • Excellent Repeatability (±0.05%), Accuracy (±0.1%)
  • Increased product quality
  • Advanced Transmitter Technology Upgrade/modernize in place
  • Optimized lifecycle management
FLOW RATE
Mass Flow Rate (max.): 650 kg/h, 24 lb/min
Volumetric Flow Rate (max.): 650 l/h, 2.86 gpm, 98 bbl/d (US)
PRESSURE
Pressure Rating: 200 bar, 2,900 psi
Optional Pressure Rating: up to 345 bar, 5000 psi
ACCURACY (LIQUIDS)¹
Basic Accuracy [Mass flow]: ±0.1 % of flow rate
Mass Flow Repeatability: ±0.05 % of flow rate
Basic Accuracy [Volume flow]: ±0.15 % of flow rate
Volume Flow Repeatability: ±0.05 % of flow rate
Zero Stability: ±0.01 % of full scale
ACCURACY (GASES)
Basic Accuracy [Mass flow]: ±0.5 % of flow rate
Mass Flow Repeatability: ±0.25 % of flow rate
DENSITY
Density Range: up to 2500 kg/m³, 2.5 g/cm³
Density Accuracy: Liquids ±1.0 kg/m³, ±0.001 g/cm³
Density Repeatability: ±0.5 kg/m³, ±0.0005 g/cm³
TEMPERATURE
Process Temperature Range: Standard:-40 °C … +100 °C (-40 °F … +212 °F)
Optional: -60 °C … +200 °C (-76 °F … +392 °F)
Temperature Accuracy: ±1 °C ±0.5 % of reading (±1.8 °F ± 0.5% of reading)
Temperature Repeatability: ±0.2 °C (±0.36 °F)
MATERIALS OF CONSTRUCTION (wetted parts)
Tubes: 1.4404/AISI 316L
Case: 1.4404/AISI 316L
Flow splitter: 1.4404/AISI 316L
Brazing Alloy: BNi-2
EX CERTIFICATIONS²
ATEX (Ex): Zone 1: Group IIC or IIB, T2…T6
ATEX (Exn): Zone 2: II 3G Ex nA IIC T2…T6 Gc
IECEx (Ex): Zone 1: Group IIC or IIB, T2…T6
cCSAus (Ex1): Class I, Division 1: Group A, B, C, D or C, D, T2…T6

 

¹Stated flow accuracy combines the effects of repeatability, linearity and hystereis.

²Release pending.

 

TRICOR® Coriolis Flow Meter TCM 0650 Pressure Drop Curves

 

TRICOR® Coriolis Mass Flow Meters Accuracy FormulaTRICOR® Coriolis Mass Flow Meters Accuracy Curve