HIGH-ACCURACY CORIOLIS FLOW & DENSITY MEASUREMENT

TCMH 0450 HP Gas

TRICOR Coriolis Mass Flow Meter TCMH 0450 for high pressure gas applications

TRICOR® Coriolis Flow Meter TCMH 0450

The TCMH 0450 is TRICOR’s High Pressure Coriolis Mass Flow Meter, offered in three pressure ratings: 6,000 psi, 10,000 psi or 15,200 psi. The material choices for the U-shape tubes are either 316 stainless steel for chemical injection applications or Sandvik® Alloy HP 160, chosen to eliminate hydrogen embrittlement, such as in Hydrogen fueling stations.

Nom. Flow Rates:
@ 20°C air, pressure drop 10 bar: 394 kg/h @ 1050 bar, 14.5 lb/min @ 15200 psi
362 kg/h @ 690 bar, 13.3 lb/min @ 10000 psi
316 kg/h @ 414 bar, 11.6 lb/min @ 6000 psi
@ 20°C H2, pressure drop 50 bar: 254 kg/h @ 1050 bar, 9.30 lb/min @ 15200 psi
240 kg/h @ 875 bar, 8.80 lb/min @ 12690 psi
222 kg/h @ 690 bar, 8.15 lb/min @ 10000 psi
184 kg/h @ 414 bar, 6.75 lb/min @ 6000 psi
Pressure Rating:
TCMH 0450-HC-SPPS (or -SPMS): 1050 bar, 15200 psi
TCMH 0450-HC-SRPS (or -SRMS) 690 bar, 10000 psi
TCMH 0450-HC-SSPS (or -SSMS): 414 bar, 6000 psi
P (1.4404/AISI 316L) = NACE compliant,
M (HP160) = not NACE compliant.
Connection: 3/8” Autoclave (MP), other connections available
  • Robust for long life
  • Delivers increased productivity
  • Customised installation length
  • Considerable cost savings for installation
  • Excellent repeatability
  • Delivers increased product quality
NOM. FLOW RATES
@ 20°C air, pressure drop 10 bar: 394 kg/h @ 1050 bar, 14.5 lb/min @ 15200 psi
362 kg/h @ 690 bar, 13.3 lb/min @ 10000 psi
316 kg/h @ 414 bar, 11.6 lb/min @ 6000 psi
@ 20°C H2, pressure drop 50 bar: 254 kg/h @ 1050 bar, 9.30 lb/min @ 15200 psi
240 kg/h @ 875 bar, 8.80 lb/min @ 12690 psi
222 kg/h @ 690 bar, 8.15 lb/min @ 10000 psi
184 kg/h @ 414 bar, 6.75 lb/min @ 6000 psi
PRESSURE
TCMH 0450-HC-SPPS (or -SPMS): 1050 bar, 15200 psi
TCMH 0450-HC-SRPS (or -SRMS): 690 bar, 10000 psi
TCMH 0450-HC-SSPS (or -SSMS): 414 bar, 6000 psi
P (1.4404/AISI 316L) = NACE compliant, M (HP160) = not NACE compliant.
CONNECTION 3/8” Autoclave (MP), other connections available
ACCURACY
Flow: ±1 % of reading
Mass Repeatability: ±0.5 % of reading
Zero Stability: 0.45 kg/h, 0.0165 lb/min
Temperature: ±1.8 °F ±0.5 % of reading (±1 °C ±0.5 % of reading)
OPERATING CONDITIONS – PROCESS Customer specific pressure compensation curves on request.
Medium Temperature: -40 °F … +212 °F (-40 °C … +100 °C)
Fluid: Gas
Pressure Effect on Sensitivity: 0.0002 %/bar, 0.000014 %/psi
OPERATING CONDITIONS – ENVIRONMENT
Ambient Temperature: -40 °F … +158 °F (-40 °C … +70 °C)
Relative Humidity: max. 95 %
MATERIAL OF CONSTRUCTION
Tubes: 1.4404/AISI 316L or Sandvik Alloy HP160.
1.4404/AISI 316L = NACE conform, HP160 = not NACE conform.
Manifold: 1.4435/AISI 316L
Housing: 1.4404/AISI 316L
BURST PROTECTION
Rupture Disc: G1/2”
CABLING
Signal Cable Connection: Push-Pull connector
For triple Ex approval (Ex3) With connector M23 (TCE) and with connector Lemo (TCM), x m cable length (TCC-06-xx).
EX CERTIFICATIONS
ATEX (Ex): Zone 1: Group IIC, T2…T4
ATEX (Exn): Zone 2: II 3G Ex nA IIC, T2…T4 Gc
IECEx (Ex): Zone 1: Group IIC, T2…T4
cCSAus (Ex1): Class I, Division 1: Group A, B, C, D, T2…T4
For cCSAus the electronic is only available in aluminum housing.
ATEX + IECEx + cCSAus triple approval (Ex3): Zone1: Group IIC, T2…T4 and Class 1, Div. 1: Group A, B, C, D, T2…T4
For Ex3 the electronic is only available in aluminum housing.

 

TRICOR® Coriolis Flow Meter TCMH 0450 Pressure Drop Curves Air

 

TRICOR® Coriolis Flow Meter TCMH 0450 Pressure Drop Curves Hydrogen