HIGH-ACCURACY CORIOLIS FLOW & DENSITY MEASUREMENT

TRICOR Coriolis Flow Transmitter TCE 8501

TCE 8501

The TCE 8501 Mass Flow Transmitter from TRICOR incorporates patented digital signal processing (DSP) that allow for continuous 2-phase measurement, partially empty tube conditions, start-from-empty batching, online flow sensor verification, and online pressure compensation.

 

Outputs available:
Analog current output and alarm
Frequency or scaled pulse output
Contact output
Programmable control inputs
Interfaces available:
HART®
Modbus
LCD Display
Hazardous area approvals:
cCSAus
IECEx
ATEX
Other approvals:
CE
GENERAL
Display LCD
Programming Via 4 softkeys on front panel (cover must be removed first)
AC Supply 102-264 VAC; 120/240 VAC nominal; 50/60Hz+/-5%
Power Consumption 18VA max
DC Supply 10-36 VDC; 24 VDC
Power Consumption 15W max
Interface RS 485 (MODBUS-RTU); Option HART
EMC  According to EN 61326-1 and IEC 61000-4-2 through 61000-4-6
Housing Material Cast aluminum alloy w/ polyester paint finish; optional epoxy power finish
Housing Rating IP66/IP67, NEMA 4X
Electrical Safety ATEX; CSA/CSAus; IECEx
Temperature Ambient: -40C to +60C (-40F to +140F)

Storage and Transport: -40C to 85C (-40F to +185F)

3 ANALOG OUTPUT (externally powered)
Current Output 4-20 mA; 22mA max, 3.9mA min
Load 0-680 Ω; 24 VDC +/-10%
2 PULSE OUTPUT
Supply 24 VDC +/-10%; 80 mA max
Frequency Range 0 to 10KHz
Duty Cycle 50% Nominal
CONTACT OUTPUT
Type Form A Relay; isolated
Supply 24 VDC +/- 10%
Current Rating 100mA max
CONTACT INPUT
Type Requires current linking device such as a contact closure or transistor switch between terminal block connections provided
Supply 24 VDC +/- 10%
Current Rating 15mA max