HIGH-ACCURACY CORIOLIS FLOW & DENSITY MEASUREMENT

TRICOR Coriolis TCE 8000 Panel Mount Version

TRICOR Coriolis Flow Transmitter TCE 8000 Panel Mount Version

Picture TRICOR® Coriolis Mass Flow Meter TCM 0325 with TCE 8000 Panel Mount

Panel mounted multi-variable Coriolis flow transmitter that can output flow rate, density, and temperature

Outputs available:
Analog current output (up to 2)
Pulse/frequency output (0.5 – 10,000 Hz)
Status output
Programmable control inputs
Interfaces available:
RS485
HART®
Foundation Fieldbus®
LCD Display
Hazardous area approvals:
ATEX
IECEx
cCSAus
GENERAL
Display: back-lit LCD screen, 132 x 32 dot
Supply Voltage: 24 V DC, ±20 % or 90 … 264 V (version dependent)
Programming: via front keyboard
or Windows-based TRICOR configurator program (Modbus)
Interface: RS485 (Modbus RTU), HART®, Foundation Fieldbus®, other options on request
EMC: according to EN 61000-6-4 and 61000-6-2
Power Consumption: max. 6 W
Electrical Connections: cage clamp terminals
Housing Material: Noryl
Protection Class: front: IP50, rear: IP30
Weight: 0.4 kg/0.88 lb
Temperature: ambient: 32 °F … +140 °F (0 °C … +60 °C)
storage and transport: -4 °F … +158 °F (-20 °C … +70 °C)
ANALOG OUTPUT
Current Outputs (2x): 4 … 20 mA passive, two-wire, isolated
Resolution: 14 bit
Linearity: ±0.05 % of full scale
Temperature Drift: 0.05 % per 10 K
Load: < 620 Ω (at 24 V supply)
Output Value: programmable: flow, total, density, temperature
PULSE OUTPUT
Frequency Range: 0.5 – 10,000 Hz
Output Signal: active push pull output for flow rate
STATUS IN- AND OUTPUT
Status Output: push pull programmable
(in TOTAL mode: 0.5 – 100 Hz; in FREQUENCY mode: 0.5 – 10,000 Hz)
Control Input: programmable
ANALOG INPUT (OPTION)
Input Type: 4 … 20 mA active for two-wire passive pressure sensor
Resolution: 12 bit
Linearity: ±0.05 % of full scale
Temperature Drift: 0.05 % per 10 K
Supply Voltage: > 20 V (at 20 mA sensor current)
EX CERTIFICATIONS
ATEX (Ex): Zone 1: Group IIC or IIB, T2…T4
ATEX (Exn): Zone 2: II 3G Ex nA IIC T2…T4 Gc
IECEx (Ex): Zone 1: Group IIC or IIB, T2…T4
cCSAus (Ex1): Class 1, Division 1: Group A, B, C, D or C, D, T2…T4
EAC (TR-CU): Group IIC or IIB, T2…T4