HIGH-ACCURACY CORIOLIS FLOW & DENSITY MEASUREMENT

TRICOR Coriolis Flow Transmitter TCE 6000

Picture TRICOR® Coriolis Mass Flow Meter TCM 0325 with TCE 6000

 

The TCE 6000 Mass Flow Transmitter is ready for ESTA applications. Outputs available include Analog current output, pulse/frequency output (0.5 to 10,000 Hz), and status output. Choose from either RS485 or HART® interfaces. It works with the TRD 8001 Remote Display.

Multi-variable Coriolis flow transmitter that can output flow rate, density, and temperature

Outputs available:
Analog current output
Pulse/frequency output (0.5 – 10,000 Hz)
Status output
Programmable control inputs
Ready for ESTA applications
Interfaces available:
RS485
HART®
GENERAL
Supply Voltage: 24 V DC, ±20 %
Programming: via TRD 8001 or via interface
Interface: RS485, USB (option)
EMC: according to EN 61000-6-4 and 61000-6-2
Power Consumption: max. 4 W
Electrical Connections: connectors M12
Housing Material: aluminum diecast
Protection Class: IP65
Temperature: ambient: -40 °F … +158 °F (-40 °C … +70 °C)
storage and transport: -40 °F … +176 °F (-40 °C … +80 °C)
ANALOG OUTPUT
Current Output: 4 … 20 mA passive
Resolution: 14 bit
Linearity: ±0.05 % of full scale
Temperature Drift: 0.05 % per 10 K
Load: < 800 Ω
Output Value: programmable: flow, total, density, temperature
PULSE OUTPUT
Frequency Range: 0.5 – 10,000 Hz
(for ESTA (OPTV receiver) 0.5 – 5,000 Hz
Output Signal: active push pull output for flow rate
optional: insulated optical pulse output
STATUS IN- AND OUTPUT
Status Output: push pull programmable (option)
(in TOTAL mode: 0.5 – 100 Hz)
Control Input: programmable (standard: 1 input/option: 2 inputs)
optional: insulated optical control input
EX CERTIFICATIONS
ATEX (Exn): Zone 2: II 3G Ex nA IIC T2…T4 Gc
Only if powered by an SELV supply.

 

 

Note: For parameterization of the flow meter, the interface may be used.
Prerequisite: Parameter setting is not allowed during active ESTA operation.