HIGH-ACCURACY CORIOLIS FLOW & DENSITY MEASUREMENT

TRICOR® Coriolis Mass Flow Meter TCM 0100

TRICOR Coriolis TCM 0100

The MicroTRICOR TCM 0100 Low Flow Coriolis Mass Meter can accurately measure low flows down to 5 cc/min, which makes it ideal for dosing, blending and batching applications such as chemical injection and precision painting/coating, as well as batch processing. The unique compact dual tube design provides for a more balanced system with greater resistance to external vibration and pulsing flow.

Mass Flow Rate (max.): 50 kg/hr, 1.84 lbs/min
Volumetric Flow Rate (max.): 50 l/h, 0.22 gpm, 7.55 bbl/d (US)
Standard Pressure Rating: up to 350 bar, 5000 psi
Tube Inner Diameter: 0.06 in, 1.52 mm
  • Ultra low flow down to 5 cc/min (300 grams/hr, 0.001 gallons/min)
  • Rated at 5,000 psi
  • No filter requirement
  • Fast response time
  • Simple to clean/flushable
  • Certified for use in hazardous areas
MEASURING RANGES
Mass Flow Rate (max.): 50 kg/hr, 1.84 lbs/min
Volumetric Flow Rate (max.): 50 l/h, 0.22 gpm, 7.55 bbl/d (US)
PRESSURE
Standard Pressure Rating: 350 bar, 5000 psi 
ACCURACY***  ***Stated flow accuracy combines the effects of repeatability, linearity and hysteresis.
Basic Accuracy [Mass flow]: ±0.2% of flow rate
Basic Accuracy [Volume flow]: ±0.25 % of flow rate
Repeatability: ±0.1 % of flow rate
Zero Stability: ±0.02% of full scale
DENSITY
Density Range: up to 4,500 kg/m³, 4.5 g/cm³
Density Accuracy: Liquids ±1.0 kg/m³, ±0.001 g/cm³
Density Repeatability: ±0.5 kg/m³, ±0.0005 g/cm³
TEMPERATURE
Process Temperature Range [Fluid]: Standard: -40 °F … +212 °F (-40 °C … +100°C)
Temperature Accuracy: ±1.0 °C ±0.5 % of reading)
Temperature Repeatability: ±0.2 °C, ±0.36 °F
PROCESS PRESSURE EFFECT* *TCE-8000 electronics offers pressure input to eliminate process pressure effect
Mass Flow Accuracy: ±0.001% of rate per psi** 
Density Accuracy: ±0.00003 g/cm³ per psi**
** 1 psi = 0.06894 bar
MATERIALS OF CONSTRUCTION
Wetted Parts: 1.4404/AISI 316L Stainless Steel
All-Welded Design

TRICOR® Coriolis Mass Flow Meters Accuracy Formula

TRICOR TCM0100_AccuracyLimits

TCM 100 Micro TRICOR Certifications